INOVANCE Hata Kodları

311 kayıt
E19.06 INOVANCE MD500-PLUS VFD

Motor auto-tuning fault - stator resistance

Olası Nedenler
  • Fault in auto-tuning on stator resistance
Çözüm
  • Ensure motor is connected
  • Set F1-03 per motor nameplate
E19.07 INOVANCE MD500-PLUS VFD

Motor auto-tuning fault - stator resistance

Olası Nedenler
  • Fault in auto-tuning on stator resistance
Çözüm
  • Ensure motor is connected
  • Set F1-03 per motor nameplate
E19.08 INOVANCE MD500-PLUS VFD

Motor auto-tuning fault - stator resistance

Olası Nedenler
  • Fault in auto-tuning on stator resistance
Çözüm
  • Ensure motor is connected
  • Set F1-03 per motor nameplate
E19.09 INOVANCE MD500-PLUS VFD

Motor auto-tuning fault - leakage inductance

Olası Nedenler
  • Fault in auto-tuning on transient leakage inductance
Çözüm
  • Check motor connection and output phase loss
  • Ensure motor connected properly
E19.10 INOVANCE MD500-PLUS VFD

Motor auto-tuning fault - leakage inductance

Olası Nedenler
  • Fault in auto-tuning on transient leakage inductance
Çözüm
  • Check motor connection and output phase loss
  • Ensure motor connected properly
E19.11 INOVANCE MD500-PLUS VFD

Inertia auto-tuning fault

Olası Nedenler
  • Inertia auto-tuning fault
Çözüm
  • Set F1-03 per motor nameplate
  • Increase value of F2-43
E19.20 INOVANCE MD500-PLUS VFD

Motor auto-tuning timeout - zero position angle

Olası Nedenler
  • Timeout of auto-tuning on no-load zero position angle of synchronous motor
Çözüm
  • Check Z feedback signal
E19.23 INOVANCE MD500-PLUS VFD

Motor auto-tuning fault - magnetic pole position

Olası Nedenler
  • Fault in auto-tuning on magnetic pole position of synchronous motor
Çözüm
  • Set F1-03 per motor nameplate
  • Decrease F2-29 (synchronous motor initial angle detection current)
E19.24 INOVANCE MD500-PLUS VFD

Motor auto-tuning fault - leakage inductance mismatch

Olası Nedenler
  • Errors in auto-tuning on transient leakage inductance
Çözüm
  • Check whether AC drive power rating is sufficient; use drive matching motor power
E20.00 INOVANCE MD500-PLUS VFD

Encoder disconnected

Olası Nedenler
  • Encoder disconnected
Çözüm
  • Restore connection
  • Ensure proper PG cable wiring
  • Ensure PG cable power supply
E20.01 INOVANCE MD500-PLUS VFD

Encoder fault

Olası Nedenler
  • Encoder fault
Çözüm
  • Restore connection
  • Ensure proper PG cable wiring
  • Ensure PG cable power supply
E20.02 INOVANCE MD500-PLUS VFD

Encoder disconnected variant

Olası Nedenler
  • Encoder disconnected
Çözüm
  • Restore connection
  • Ensure proper PG cable wiring
  • Ensure PG cable power supply
E20.03 INOVANCE MD500-PLUS VFD

Encoder fault during no-load auto-tuning

Olası Nedenler
  • Encoder fault during no-load auto-tuning of synchronous motor
Çözüm
  • Restore connection
  • Ensure proper PG cable wiring
  • Ensure PG cable power supply
E20.04 INOVANCE MD500-PLUS VFD

Encoder fault during no-load auto-tuning

Olası Nedenler
  • Encoder fault during no-load auto-tuning of synchronous motor
Çözüm
  • Restore connection
  • Ensure proper PG cable wiring
  • Ensure PG cable power supply
E20.06 INOVANCE MD500-PLUS VFD

Encoder fault during with-load auto-tuning

Olası Nedenler
  • Encoder fault during with-load auto-tuning of synchronous motor
Çözüm
  • Restore connection
  • Ensure proper PG cable wiring
  • Ensure PG cable power supply
E20.07 INOVANCE MD500-PLUS VFD

Encoder fault during no-load auto-tuning

Olası Nedenler
  • Encoder fault during no-load auto-tuning of synchronous motor
Çözüm
  • Restore connection
  • Ensure proper PG cable wiring
  • Ensure PG cable power supply
E20.08 INOVANCE MD500-PLUS VFD

Encoder fault during no-load auto-tuning

Olası Nedenler
  • Encoder fault during no-load auto-tuning of synchronous motor
Çözüm
  • Restore connection
  • Ensure proper PG cable wiring
  • Ensure PG cable power supply
E20.09 INOVANCE MD500-PLUS VFD

Encoder fault during auto-tuning - Z signal

Olası Nedenler
  • Encoder fault during auto-tuning of synchronous motor
Çözüm
  • Check encoder Z signal and PG card wiring
E20.10 INOVANCE MD500-PLUS VFD

Synchronous motor encoder fault

Olası Nedenler
  • Synchronous motor encoder fault
Çözüm
  • Check encoder Z signal and PG card wiring
E20.11 INOVANCE MD500-PLUS VFD

Encoder fault during FVC no-load auto-tuning

Olası Nedenler
  • Encoder fault during FVC no-load auto-tuning of asynchronous motor
Çözüm
  • Ensure encoder properly connected
  • Ensure encoder PPR matches F1-27