INOVANCE Hata Kodları

311 kayıt
E017.1 INOVANCE MD520 VFD

Contactor fault

Olası Nedenler
  • Drive board and power supply exception
  • Contactor exception
  • Surge protector exception
Çözüm
  • Replace drive board or power supply board
  • Replace contactor
  • Replace surge protector
E018.1 INOVANCE MD520 VFD

Current detection fault

Olası Nedenler
  • Hall component exception
  • AC drive stopped while synchronous motor rotating at high speed
  • Drive board exception
Çözüm
  • Replace hall component
  • Disable zero drift detection by setting bit07 of BF-07
  • Replace drive board
E019.1 INOVANCE MD520 VFD

Auto-tuning timeout

Olası Nedenler
  • Motor parameter setting exception or AC drive model setting exception
Çözüm
  • Set motor and AC drive parameters correctly
E019.2 INOVANCE MD520 VFD

Auto-tuning interruption

Olası Nedenler
  • Auto-tuning interrupted by stop command
Çözüm
  • Wait until auto-tuning completed; motor stops automatically
E019.3 INOVANCE MD520 VFD

Overcurrent during auto-tuning

Olası Nedenler
  • Current out-of-control during auto-tuning
Çözüm
  • Set motor parameters and AC drive model correctly
  • Contact technical support
E019.4 INOVANCE MD520 VFD

Auto-tuning back EMF exception

Olası Nedenler
  • Basic motor parameter setting error
  • Oscillation suppression failure
Çözüm
  • Set motor nameplate parameters and AC drive model correctly
  • Adjust oscillation suppression parameter
E019.7 INOVANCE MD520 VFD

No-load current auto-tuning error

Olası Nedenler
  • No-load current out-of-range during motor auto-tuning
Çözüm
  • Set motor nameplate parameters and AC drive model correctly
E02.00 INOVANCE MD500-PLUS VFD

Overcurrent during acceleration

Olası Nedenler
  • Grounded or short-circuited output circuit
  • Auto-tuning not performed in SVC/FVC mode
  • Excessively short acceleration time
Çözüm
  • Check motor and relay contactor for short circuit
  • Set motor parameters per nameplate and perform auto-tuning
  • Increase acceleration time (F0-17)
E020.1 INOVANCE MD520 VFD

Encoder hardware wire breakage

Olası Nedenler
  • Encoder hardware feedback signal exception
Çözüm
  • Check correct PG card selected
  • Check wiring
  • Check encoder
E020.2 INOVANCE MD520 VFD

Encoder PPR error

Olası Nedenler
  • Inconsistency between encoder feedback speed and actual motor speed
Çözüm
  • Check ABZ encoder PPR or number of pole pairs of resolver
E020.3 INOVANCE MD520 VFD

No encoder feedback

Olası Nedenler
  • No encoder feedback speed
Çözüm
  • Check correct PG card selected
  • Check wiring
  • Check encoder
E020.4 INOVANCE MD520 VFD

Encoder direction fault

Olası Nedenler
  • Encoder direction opposite to motor rotation direction
Çözüm
  • Set F1-30 to switch encoder direction
E020.5 INOVANCE MD520 VFD

Large encoder feedback speed fluctuation

Olası Nedenler
  • Sudden change of encoder feedback speed
Çözüm
  • Check correct PG card
  • Check wiring
  • Check encoder
E020.8 INOVANCE MD520 VFD

ABZ encoder Z signal loss

Olası Nedenler
  • ABZ encoder Z signal loss
Çözüm
  • Reported only during self-check when synchronous motor uses ABZ encoder in FVC mode
E020.9 INOVANCE MD520 VFD

Encoder pulse interference

Olası Nedenler
  • Encoder feedback speed fluctuation exception
Çözüm
  • Reported only during self-check of encoder
E021.1 INOVANCE MD520 VFD

EEPROM read-write fault

Olası Nedenler
  • EEPROM read-write exception
Çözüm
  • For parameters written through communication check RAM addresses and address mapping
  • If EEPROM chip damaged contact manufacturer to replace main control board
E021.2 INOVANCE MD520 VFD

EEPROM read-write fault

Olası Nedenler
  • EEPROM read-write exception
Çözüm
  • For parameters written through communication check RAM addresses and address mapping
  • If EEPROM chip damaged contact manufacturer to replace main control board
E021.3 INOVANCE MD520 VFD

EEPROM read-write fault

Olası Nedenler
  • EEPROM read-write exception
Çözüm
  • For parameters written through communication check RAM addresses
  • If EEPROM chip damaged contact manufacturer
E021.4 INOVANCE MD520 VFD

EEPROM read-write fault

Olası Nedenler
  • EEPROM read-write exception
Çözüm
  • For parameters written through communication check RAM addresses